Grainforce Pty Ltd

EPL21073 - Grainforce - Raglan

Address: 148 Ceramic Drive, Raglan NSW 2795

December 2018

Date Received: 23/01/2019

Date Published: 23/01/2019

EPA Point 1 Point Description: Within each fumigated container prior to ventilation
Pollutant Unit of Measure Monitoring frequency required by licence No. times measured during the month Min. Value Avg. Value Max. Value 100 percentile limit Exceedance
(Yes/No)
Methyl bromide grams/cubic metre At each container 431 22 23.65 27 48 No

November 2018

Date Received: 05/12/2018

Date Published: 05/12/2018

EPA Point 1 Point Description: Within each fumigated container prior to ventilation
Pollutant Unit of Measure Monitoring frequency required by licence No. times measured during the month Min. Value Avg. Value Max. Value 100 percentile limit Exceedance
(Yes/No)
Methyl bromide grams/cubic metre At each container 478 22 24.31 29 48 No

October 2018

Date Received: 21/11/2018

Date Published: 21/11/2018

EPA Point 1 Point Description: Within each fumigated container prior to ventilation
Pollutant Unit of Measure Monitoring frequency required by licence No. times measured during the month Min. Value Avg. Value Max. Value 100 percentile limit Exceedance
(Yes/No)
Methyl bromide grams/cubic metre At each container 422 22 24.94 29 48 No

September 2018

Date Received: 09/10/2018

Date Published: 10/10/2018

EPA Point 1 Point Description: Within each fumigated container prior to ventilation
Pollutant Unit of Measure Monitoring frequency required by licence No. times measured during the month Min. Value Avg. Value Max. Value 100 percentile limit Exceedance
(Yes/No)
Methyl bromide grams/cubic metre At each container 408 24 26.01 32 48 No

August 2018

Date Received: 17/09/2018

Date Published: 20/09/2018

EPA Point 1 Point Description: Within each fumigated container prior to ventilation
Pollutant Unit of Measure Monitoring frequency required by licence No. times measured during the month Min. Value Avg. Value Max. Value 100 percentile limit Exceedance
(Yes/No)
Methyl bromide grams/cubic metre At each container 416 24 28.0 33 48 No

July 2018

Date Received: 15/08/2018

Date Published: 15/08/2018

EPA Point 1 Point Description: Within each fumigated container prior to ventilation
Pollutant Unit of Measure Monitoring frequency required by licence No. times measured during the month Min. Value Avg. Value Max. Value 100 percentile limit Exceedance
(Yes/No)
Methyl bromide grams/cubic metre At each container 541 20 28.2 33 48 No

June 2018

Date Received: 04/07/2018

Date Published: 04/07/2018

EPA Point 1 Point Description: Within each fumigated container prior to ventilation
Pollutant Unit of Measure Monitoring frequency required by licence No. times measured during the month Min. Value Avg. Value Max. Value 100 percentile limit Exceedance
(Yes/No)
Methyl bromide grams/cubic metre At each container 461 24 28.7 33 48 No

May 2018

Date Received: 04/06/2018

Date Published: 08/06/2018

EPA Point 1 Point Description: Within each fumigated container prior to ventilation
Pollutant Unit of Measure Monitoring frequency required by licence No. times measured during the month Min. Value Avg. Value Max. Value 100 percentile limit Exceedance
(Yes/No)
Methyl bromide grams/cubic metre At each container 593 24 24.0 33 48 No

April 2018

Date Received: 02/05/2018

Date Published: 02/05/2018

Date Corrected: 07/06/2018

EPA Point 1 Point Description: Within each fumigated container prior to ventilation
Pollutant Unit of Measure Monitoring frequency required by licence No. times measured during the month Min. Value Avg. Value Max. Value 100 percentile limit Exceedance
(Yes/No)
Methyl bromide grams/cubic metre At each container 488 24 29.1 33 48 No

Correction Log

07/06/2018

On 06/06/2018 we received information from our fumigator advising that they omitted the data for 13 containers in the April data set. This changed the No.times measured during the month from 475 to 488 and the Avg. value from 28.0 to 29.1.

March 2018

Date Received: 02/05/2018

Date Published: 02/05/2018

EPA Point 1 Point Description: Within each fumigated container prior to ventilation
Pollutant Unit of Measure Monitoring frequency required by licence No. times measured during the month Min. Value Avg. Value Max. Value 100 percentile limit Exceedance
(Yes/No)
Methyl bromide grams/cubic metre At each container 110 27 28.0 33 48 No